Specifications
- Feature:Hair Removal Skin Rejuvenation
- Certification:CE
- Item Code:823483996
- Category:IPL Machine
Return policy details
- Buyers can return item(s) for a refund within 7 days from the day the item(s) were received, and the buyer is to afford the return shipping cost. The item(s) must be returned in the same exact condition as once it was delivered.
- Buyers may return the item(s) for a refund if they are not as described or with quality issues within 7 days from the day the item(s) were received.The buyer is required to afford the return shipping cost, based on the condition of the item(s) received.
Description
Diode Laser Hair Removal Machine Certified New E-light IPL OPT Permanent Hair RemoverSkin Rejuvenation Beauty EquipmentSalon Hospital Use
Product Description
Product Description OPT is with new AFT technology uses
low and equal energy. The special filter cuts 950-1200nm wavelength, which is
useless in treatment and absorbs water to make patient feel painless.
The machine can achieve permanent hair removal.The system combines laser technology and the benefits
of the pulsating light method achieving practically painless results. Even hairs which
until now have been difficult or even impossible to be removed, can now be treated.
In Motion represents a breakthrough in permanent hair removal with light
technology. The treatment is more pleasant than with the conventional systems and
your skin is better protected.
How to use the OPT ?
Clinic operation
A. Before treatment
To the machine:
b). Input enough water and make good water circulation before actual operation
c). Water source: distilled water or pure water
d). Before the operation, make sure probe cold. Then it`s able to start the operation. (if
take operation under the state of no water circulation or hot probe, the handpiece is
easy to damaged.)
e). Inflammable and explosive things should be kept away from operating room, such
as stupefacient ,liquid and gas.
To the patients:
a). Classification of skin: it`s safe and effective to the white, brown or yellow skin.
b). Clean skin to eliminate the perfume and cosmetics.
c). Use digital camera for memory, take photo from different orientations, if necessary
d). If necessary, use external anesthetic one hour before the treatment; Please shave
hair firstly under hair removal treatment.
f). Spread the cooling gel on skin, about 2 mm thickness
g). Wear eyepatch before actual option
Note: can not look at the intensive pulsed light directly, or alarm to people`s eyes, such
as keratitis, cornea brushing off, or even lose sight.
h). forbidden to wear watch and necklace etc. during the treatment.
To the operators:
a). Adjust the right parameters
b). Touch the on the LCD to start
c). Test the device working, please shot the 3 first pulse to ground at beginning,
make sure even energy output in treatment.
d). Wear glasses before actual option
e). forbidden to wear watch and necklace etc. during the treatment.
f). can not look at the intensive pulsed light directly, or alarm to people`s eyes, such as
keratitis,cornea brushing off, or even lose sight.
g). Please do not optionally open the panel of the machine even power stopped, in
case high voltage danger.
h). It must tighten up the screw caps of machine before movement.
i). vertically slide the probe on skin, and keep close to skin
J). Keep the machine rest every 2 to 3 hours continuously working
k). The handle is fragile, please keep special care when hanging to the holder or in
handle
l). Please do treatment from the lower energy at the beginning, and adjust the energy
according to actual conditions.
System alarm of water temperature:
The lowest system settings of water temperature is 25 degree the highest system
setting of water temperature is 60 degree. During 25---60 degree, the machine
works well. If lower 25 degree or higher 60C,now pulse output from the probe.
Taboos(who are not suitable to use this machine?)
a) Pregnant
b) Isolation in the sun
c) Sensitive to light or medicine, or are taking medicine that sensitive to light
d) Using vitamin within 6 months
e) Not representative naevi or malignant pathological changes in the treatment area.
f) Pacemaker or quiver dispelling device user
g) Herpes or trauma
h) Pimple record
i) People who accept Hirudin etc. treatment (should stop using it before 2 weeks).
j) Severe diabetes patient, high blood pressure sufferer, and epileptic
Technical Parameter
Wavelength 480-950nm or 530-950nm or 640-950nm
Counter Handle Yes
Spot size 15*50mm2
Energy 1-36J/cm2
Pulse repetition rate 1-10 Hz
Continually shooting timer 1-30s
Pulse Single
Pulse on 2-15ms
Water temperature tank 38 degree
Display system 8.4 colorful touch screen
Drive Power 2,000W
Packing List
Main device
1pcs
OPT Handle 1pcs
Filters 3pcs
Water Funnel 1pcs
Protective Eyepatch 1pcs
Protective Glasses 1pcs
Holder 1pcs
Fuse 2pcs
Power cord 1pcs
User manual 1book
More Description
1 Customer Reviews
55 stars
5(1)
Reviews
-
jm.***ley
May 21, 2023
Options: 110V US Plug
Default 5-star ratings by platform because the buyer did not leave timely reviews.
Sponsored Products You May be Interested In More Choice
我也要出现在这里
Related Keywords
- spa machine for hair
- ipl hair removal prices
- electrolysis machine
- mask for hair
- permanent facial hair removal for women
- automatic turner egg incubator
- medical hair
- pulse light treatment
- hair removal prices
- beekeeping equipment
- intense pulsed light machines